1.
Lancet Digit Health ; 6(4): e251-e260, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38519153

RESUMO

BACKGROUND: The diagnosis of cardiac amyloidosis can be established non-invasively by scintigraphy using bone-avid tracers, but visual assessment is subjective and can lead to misdiagnosis. We aimed to develop and validate an artificial intelligence (AI) system for standardised and reliable screening of cardiac amyloidosis-suggestive uptake and assess its prognostic value, using a multinational database of 99mTc-scintigraphy data across multiple tracers and scanners. METHODS: In this retrospective, international, multicentre, cross-tracer development and validation study, 16 241 patients with 19 401 scans were included from nine centres: one hospital in Austria (consecutive recruitment Jan 4, 2010, to Aug 19, 2020), five hospital sites in London, UK (consecutive recruitment Oct 1, 2014, to Sept 29, 2022), two centres in China (selected scans from Jan 1, 2021, to Oct 31, 2022), and one centre in Italy (selected scans from Jan 1, 2011, to May 23, 2023). The dataset included all patients referred to whole-body 99mTc-scintigraphy with an anterior view and all 99mTc-labelled tracers currently used to identify cardiac amyloidosis-suggestive uptake. Exclusion criteria were image acquisition at less than 2 h (99mTc-3,3-diphosphono-1,2-propanodicarboxylic acid, 99mTc-hydroxymethylene diphosphonate, and 99mTc-methylene diphosphonate) or less than 1 h (99mTc-pyrophosphate) after tracer injection and if patients' imaging and clinical data could not be linked. Ground truth annotation was derived from centralised core-lab consensus reading of at least three independent experts (CN, TT-W, and JN). An AI system for detection of cardiac amyloidosis-associated high-grade cardiac tracer uptake was developed using data from one centre (Austria) and independently validated in the remaining centres. A multicase, multireader study and a medical algorithmic audit were conducted to assess clinician performance compared with AI and to evaluate and correct failure modes. The system's prognostic value in predicting mortality was tested in the consecutively recruited cohorts using cox proportional hazards models for each cohort individually and for the combined cohorts. FINDINGS: The prevalence of cases positive for cardiac amyloidosis-suggestive uptake was 142 (2%) of 9176 patients in the Austrian, 125 (2%) of 6763 patients in the UK, 63 (62%) of 102 patients in the Chinese, and 103 (52%) of 200 patients in the Italian cohorts. In the Austrian cohort, cross-validation performance showed an area under the curve (AUC) of 1·000 (95% CI 1·000-1·000). Independent validation yielded AUCs of 0·997 (0·993-0·999) for the UK, 0·925 (0·871-0·971) for the Chinese, and 1·000 (0·999-1·000) for the Italian cohorts. In the multicase multireader study, five physicians disagreed in 22 (11%) of 200 cases (Fleiss' kappa 0·89), with a mean AUC of 0·946 (95% CI 0·924-0·967), which was inferior to AI (AUC 0·997 [0·991-1·000], p=0·0040). The medical algorithmic audit demonstrated the system's robustness across demographic factors, tracers, scanners, and centres. The AI's predictions were independently prognostic for overall mortality (adjusted hazard ratio 1·44 [95% CI 1·19-1·74], p<0·0001). INTERPRETATION: AI-based screening of cardiac amyloidosis-suggestive uptake in patients undergoing scintigraphy was reliable, eliminated inter-rater variability, and portended prognostic value, with potential implications for identification, referral, and management pathways. FUNDING: Pfizer.


Assuntos
Amiloidose , Cardiomiopatias , Humanos , Amiloidose/diagnóstico por imagem , Amiloidose/metabolismo , Inteligência Artificial , Cardiomiopatias/diagnóstico por imagem , Cardiomiopatias/metabolismo , Prognóstico , Cintilografia , Compostos Radiofarmacêuticos , Estudos Retrospectivos
2.
J Nucl Med ; 64(1): 96-101, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-35835583

RESUMO

18F-FDG PET/MRI might be the diagnostic method of choice for Hodgkin lymphoma patients, as it combines significant metabolic information from PET with excellent soft-tissue contrast from MRI and avoids radiation exposure from CT. However, a major issue is longer examination times than for PET/CT, especially for younger children needing anesthesia. Thus, a targeted selection of suitable whole-body MRI sequences is important to optimize the PET/MRI workflow. Methods: The initial PET/MRI scans of 84 EuroNet-PHL-C2 study patients from 13 international PET centers were evaluated. In each available MRI sequence, 5 PET-positive lymph nodes were assessed. If extranodal involvement occurred, 2 splenic lesions, 2 skeletal lesions, and 2 lung lesions were also assessed. A detection rate was calculated dividing the number of visible, anatomically assignable, and measurable lesions in the respective MRI sequence by the total number of lesions. Results: Relaxation time-weighted (T2w) transverse sequences with fat saturation (fs) yielded the best result, with detection rates of 95% for nodal lesions, 62% for splenic lesions, 94% for skeletal lesions, and 83% for lung lesions, followed by T2w transverse sequences without fs (86%, 49%, 16%, and 59%, respectively) and longitudinal relaxation time-weighted contrast-enhanced transverse sequences with fs (74%, 35%, 57%, and 55%, respectively). Conclusion: T2w transverse sequences with fs yielded the highest detection rates and are well suited for accurate whole-body PET/MRI in lymphoma patients. There is no evidence to recommend the use of contrast agents.


Assuntos
Doenças Ósseas , Doença de Hodgkin , Humanos , Criança , Doença de Hodgkin/diagnóstico por imagem , Doença de Hodgkin/patologia , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Fluxo de Trabalho , Imagem de Difusão por Ressonância Magnética/métodos , Imageamento por Ressonância Magnética/métodos , Tomografia por Emissão de Pósitrons/métodos , Fluordesoxiglucose F18 , Imagem Corporal Total/métodos , Estadiamento de Neoplasias , Compostos Radiofarmacêuticos
3.
Heart ; 108(21): e7, 2022 10 13.
Artigo em Inglês | MEDLINE | ID: mdl-35613713

RESUMO

Heart and circulatory diseases affect more than seven million people in the UK. Non-invasive cardiac imaging is a critical element of contemporary cardiology practice. Progressive improvements in technology over the last 20 years have increased diagnostic accuracy in all modalities and led to the incorporation of non-invasive imaging into many standard cardiac clinical care pathways. Cardiac imaging tests are requested by a variety of healthcare practitioners and performed in a range of settings from the most advanced hospitals to local health centres. Imaging is used to detect the presence and consequences of cardiovascular disease, as well as to monitor the response to therapies. The previous UK national imaging strategy statement which brought together all of the non-invasive imaging modalities was published in 2010. The purpose of this document is to collate contemporary standards developed by the modality-specific professional organisations which make up the British Cardiovascular Society Imaging Council, bringing together common and essential recommendations. The development process has been inclusive and iterative. Imaging societies (representing both cardiology and radiology) reviewed and agreed on the initial structure. The final document therefore represents a position, which has been generated inclusively, presents rigorous standards, is applicable to clinical practice and deliverable. This document will be of value to a variety of healthcare professionals including imaging departments, the National Health Service or other organisations, regulatory bodies, commissioners and other purchasers of services, and service users, i.e., patients, and their relatives.


Assuntos
Cardiologia , Doenças Cardiovasculares , Doenças Cardiovasculares/diagnóstico por imagem , Diagnóstico por Imagem , Humanos , Sociedades , Medicina Estatal , Reino Unido
4.
J Nucl Med Technol ; 50(3): 256-262, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35440476

RESUMO

18F-FDG PET/CT quantification of whole-body tumor burden in lymphoma is not routinely performed because of the lack of fast methods. Although the semiautomatic method is fast, it is not fast enough to quantify tumor burden in daily clinical practice. Our purpose was to evaluate the performance of convolutional neural network (CNN) software in localizing neoplastic lesions in whole-body 18F-FDG PET/CT images of pediatric lymphoma patients. Methods: The retrospective image dataset, derived from the data pool of the International Atomic Energy Agency (coordinated research project E12017), included 102 baseline staging 18F-FDG PET/CT studies of pediatric lymphoma patients (mean age, 11 y). The images were quantified to determine the whole-body tumor burden (whole-body metabolic tumor volume [wbMTV] and whole-body total lesion glycolysis [wbTLG]) using semiautomatic software and CNN-based software. Both were displayed as semiautomatic wbMTV and wbTLG and as CNN wbMTV and wbTLG. The intraclass correlation coefficient (ICC) was applied to evaluate concordance between the CNN-based software and the semiautomatic software. Results: Twenty-six patients were excluded from the analysis because the software was unable to perform calculations for them. In the remaining 76 patients, CNN and semiautomatic wbMTV tumor burden metrics correlated strongly (ICC, 0.993; 95% CI, 0.989 - 0.996; P < 0.0001), as did CNN and semiautomatic wbTLG (ICC, 0.999; 95% CI, 0.998-0.999; P < 0.0001). However, the time spent calculating these metrics was significantly (<0.0001) less by CNN (mean, 19 s; range, 11-50 s) than by the semiautomatic method (mean, 21.6 min; range, 3.2-62.1 min), especially in patients with advanced disease. Conclusion: Determining whole-body tumor burden in pediatric lymphoma patients using CNN is fast and feasible in clinical practice.


Assuntos
Fluordesoxiglucose F18 , Linfoma , Criança , Fluordesoxiglucose F18/metabolismo , Humanos , Linfoma/diagnóstico por imagem , Redes Neurais de Computação , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Estudos Retrospectivos , Carga Tumoral
6.
J Nucl Cardiol ; 29(5): 2119-2128, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34169473

RESUMO

BACKGROUND: International guidance recognizes the shortcomings of the modified Duke Criteria (mDC) in diagnosing infective endocarditis (IE) when transoesophageal echocardiography (TOE) is equivocal. 18F-FDG PET/CT (PET) has proven benefit in prosthetic valve endocarditis (PVE), but is restricted to extracardiac manifestations in native disease (NVE). We investigated the incremental benefit of PET over the mDC in NVE. METHODS: Dual-center retrospective study (2010-2018) of patients undergoing myocardial suppression PET for NVE and PVE. Cases were classified by mDC pre- and post-PET, and evaluated against discharge diagnosis. Receiver Operating Characteristic (ROC) analysis and net reclassification index (NRI) assessed diagnostic performance. Valve standardized uptake value (SUV) was recorded. RESULTS: 69/88 PET studies were evaluated across 668 patients. At discharge, 20/32 had confirmed NVE, 22/37 PVE, and 19/69 patients required surgery. PET accurately re-classified patients from possible, to definite or rejected (NRI: NVE 0.89; PVE 0.90), with significant incremental benefit in both NVE (AUC 0.883 vs 0.750) and PVE (0.877 vs 0.633). Sensitivity and specificity were 75% and 92% in NVE; 87% and 86% in PVE. Duration of antibiotics and C-reactive Protein level did not impact performance. No diagnostic SUV cut-off was identified. CONCLUSION: PET improves diagnostic certainty when combined with mDC in NVE and PVE.


Assuntos
Endocardite Bacteriana , Endocardite , Próteses Valvulares Cardíacas , Infecções Relacionadas à Prótese , Antibacterianos , Proteína C-Reativa , Endocardite/diagnóstico por imagem , Endocardite Bacteriana/diagnóstico , Fluordesoxiglucose F18 , Próteses Valvulares Cardíacas/efeitos adversos , Humanos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Infecções Relacionadas à Prótese/diagnóstico por imagem , Estudos Retrospectivos
7.
IEEE Access ; 9: 108873-108888, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34395149

RESUMO

Early detection and diagnosis of coronary artery disease could reduce the risk of developing a heart attack. The coronary arteries are optimally visualised using computed tomography coronary angiography (CTCA) imaging. These images are reviewed by specialist radiologists who evaluate the coronary arteries for potential narrowing. A lack of radiologists in the UK is a constraint to timely diagnosis of coronary artery disease, particularly in the acute accident and emergency department setting. The development of automated methods by which coronary artery narrowing can be identified rapidly and accurately are therefore timely. Such complex computer based tools also need to be sufficiently computationally efficient that they can run on servers typically found in hospital settings, where graphical processing units for example are unavailable. We propose a fully automatic two-dimensional Unet model to segment the aorta and coronary arteries on CTCA images. Two models are trained to segment two regions of interest, (1) the aorta and the coronary arteries or (2) the coronary arteries alone. Our method achieves 91.20% and 88.80% dice similarity coefficient accuracy on regions of interest 1 and 2 respectively. Compared with a semi-automatic segmentation method, our model performs better when segmenting the coronary arteries alone. The performance of the proposed method is comparable to existing published two-dimensional or three-dimensional deep learning models. Importantly, the algorithmic and graphical processing unit memory efficiencies are maintained such that the model can be deployed without requiring graphical processing units, and therefore can be used in a hospital setting.

8.
J Nucl Med ; 62(11): 1524-1530, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-33608429

RESUMO

Treatment regimens for pediatric Hodgkin lymphoma (HL) depend on accurate staging and treatment response assessment, based on accurate disease distribution and metabolic activity depiction. With the aim of radiation dose reduction, we compared the diagnostic performance of 18F-FDG PET/MRI with a 18F-FDG PET/CT reference standard for staging and response assessment. Methods: Twenty-four patients (mean age, 15.4 y; range, 8-19.5 y) with histologically proven HL were prospectively and consecutively recruited in 2015 and 2016, undergoing both 18F-FDG PET/CT and 18F-FDG PET/MRI at initial staging (n = 24) and at response assessment (n = 21). The diagnostic accuracy of 18F-FDG PET/MRI for both nodal and extranodal disease was compared with that of 18F-FDG PET/CT, which was considered the reference standard. Discrepancies were retrospectively classified as perceptual or technical errors, and 18F-FDG PET/MRI and 18F-FDG PET/CT were corrected by removing perceptual error. Agreement with Ann Arbor staging and Deauville grading was also assessed. Results: For nodal and extranodal sites combined, corrected staging 18F-FDG PET/MRI sensitivity was 100% (95% CI, 96.7%-100%) and specificity was 99.5% (95% CI, 98.3%-99.9%). Corrected response-assessment 18F-FDG PET/MRI sensitivity was 83.3% (95% CI, 36.5%-99.1%) and specificity was 100% (95% CI, 99.2%-100%). Modified Ann Arbor staging agreement between 18F-FDG PET/CT and 18F-FDG PET/MRI was perfect (κ = 1.0, P = 0.000). Deauville grading agreement between 18F-FDG PET/MRI and 18F-FDG PET/CT was excellent (κ = 0.835, P = 0.000). Conclusion:18F-FDG PET/MRI is a promising alternative to 18F-FDG PET/CT for staging and response assessment in children with HL.


Assuntos
Fluordesoxiglucose F18 , Doença de Hodgkin , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Humanos , Estudos Retrospectivos
9.
Neuroradiology ; 63(7): 1043-1052, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33392734

RESUMO

PURPOSE: To assess the potential role of computed tomography (CT) texture analysis (CTTA) in identifying vulnerable patients with carotid artery atherosclerosis. METHODS: In this case-control pilot study, 12 patients with carotid atherosclerosis and a subsequent history of transient ischemic attack or stroke were age and sex matched with 12 control cases with asymptomatic carotid atherosclerosis (follow-up time 103.58 ± 9.2 months). CTTA was performed using a commercially available research software package (TexRAD) by an operator blinded to clinical data. CTTA comprised a filtration-histogram technique to extract features at different scales corresponding to spatial scale filter (fine = 2 mm, medium = 3 mm, coarse = 4 mm), followed by quantification using histogram-based statistical parameters: mean, kurtosis, skewness, entropy, standard deviation, and mean value of positive pixels. A single axial slice was selected to best represent the largest cross-section of the carotid bifurcation or the greatest degree of stenosis, in presence of an atherosclerotic plaque, on each side. RESULTS: CTTA revealed a statistically significant difference in skewness between symptomatic and asymptomatic patients at the medium (0.22 ± 0.35 vs - 0.18 ± 0.39, p < 0.001) and coarse (0.23 ± 0.22 vs 0.03 ± 0.29, p = 0.003) texture scales. At the fine-texture scale, skewness (0.20 ± 0.59 vs - 0.18 ± 0.58, p = 0.009) and standard deviation (366.11 ± 117.19 vs 300.37 ± 82.51, p = 0.03) were significant before correction. CONCLUSION: Our pilot study highlights the potential of CTTA to identify vulnerable patients in stroke and TIA. CT texture may have the potential to act as a novel risk stratification tool in patients with carotid atherosclerosis.


Assuntos
Artérias Carótidas , Tomografia Computadorizada por Raios X , Estudos de Casos e Controles , Humanos , Avaliação de Resultados em Cuidados de Saúde , Projetos Piloto
10.
Front Cardiovasc Med ; 8: 795195, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-35004905

RESUMO

Coronary artery bypass graft (CABG) surgery effectively relieves symptoms and improves outcomes. However, patients undergoing CABG surgery typically have advanced coronary atherosclerotic disease and remain at high risk for symptom recurrence and adverse events. Functional non-invasive testing for ischaemia is commonly used as a gatekeeper for invasive coronary and graft angiography, and for guiding subsequent revascularisation decisions. However, performing and interpreting non-invasive ischaemia testing in patients post CABG is challenging, irrespective of the imaging modality used. Multiple factors including advanced multi-vessel native vessel disease, variability in coronary hemodynamics post-surgery, differences in graft lengths and vasomotor properties, and complex myocardial scar morphology are only some of the pathophysiological mechanisms that complicate ischaemia evaluation in this patient population. Systematic assessment of the impact of these challenges in relation to each imaging modality may help optimize diagnostic test selection by incorporating clinical information and individual patient characteristics. At the same time, recent technological advances in cardiac imaging including improvements in image quality, wider availability of quantitative techniques for measuring myocardial blood flow and the introduction of artificial intelligence-based approaches for image analysis offer the opportunity to re-evaluate the value of ischaemia testing, providing new insights into the pathophysiological processes that determine outcomes in this patient population.

11.
J Am Coll Cardiol ; 77(2): 128-139, 2021 01 19.
Artigo em Inglês | MEDLINE | ID: mdl-33181246

RESUMO

BACKGROUND: Older patients with severe aortic stenosis (AS) are increasingly identified as having cardiac amyloidosis (CA). It is unknown whether concomitant AS-CA has worse outcomes or results in futility of transcatheter aortic valve replacement (TAVR). OBJECTIVES: This study identified clinical characteristics and outcomes of AS-CA compared with lone AS. METHODS: Patients who were referred for TAVR at 3 international sites underwent blinded research core laboratory 99mtechnetium-3,3-diphosphono-1,2-propanodicarboxylic acid (DPD) bone scintigraphy (Perugini grade 0: negative; grades 1 to 3: increasingly positive) before intervention. Transthyretin-CA (ATTR) was diagnosed by DPD and absence of a clonal immunoglobulin, and light-chain CA (AL) was diagnosed via tissue biopsy. National registries captured all-cause mortality. RESULTS: A total of 407 patients (age 83.4 ± 6.5 years; 49.8% men) were recruited. DPD was positive in 48 patients (11.8%; grade 1: 3.9% [n = 16]; grade 2/3: 7.9% [n = 32]). AL was diagnosed in 1 patient with grade 1. Patients with grade 2/3 had worse functional capacity, biomarkers (N-terminal pro-brain natriuretic peptide and/or high-sensitivity troponin T), and biventricular remodeling. A clinical score (RAISE) that used left ventricular remodeling (hypertrophy/diastolic dysfunction), age, injury (high-sensitivity troponin T), systemic involvement, and electrical abnormalities (right bundle branch block/low voltages) was developed to predict the presence of AS-CA (area under the curve: 0.86; 95% confidence interval: 0.78 to 0.94; p < 0.001). Decisions by the heart team (DPD-blinded) resulted in TAVR (333 [81.6%]), surgical AVR (10 [2.5%]), or medical management (65 [15.9%]). After a median of 1.7 years, 23% of patients died. One-year mortality was worse in all patients with AS-CA (grade: 1 to 3) than those with lone AS (24.5% vs. 13.9%; p = 0.05). TAVR improved survival versus medical management; AS-CA survival post-TAVR did not differ from lone AS (p = 0.36). CONCLUSIONS: Concomitant pathology of AS-CA is common in older patients with AS and can be predicted clinically. AS-CA has worse clinical presentation and a trend toward worse prognosis, unless treated. Therefore, TAVR should not be withheld in AS-CA.


Assuntos
Amiloidose/epidemiologia , Estenose da Valva Aórtica/mortalidade , Idoso , Idoso de 80 Anos ou mais , Amiloidose/complicações , Amiloidose/diagnóstico por imagem , Estenose da Valva Aórtica/complicações , Áustria/epidemiologia , Feminino , Humanos , Masculino , Prevalência , Estudos Prospectivos , Cintilografia , Estados Unidos/epidemiologia
12.
JACC Cardiovasc Imaging ; 13(10): 2177-2189, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32771574

RESUMO

OBJECTIVES: The purpose of this study was to validate computed tomography measured ECV (ECVCT) as part of routine evaluation for the detection of cardiac amyloid in patients with aortic stenosis (AS)-amyloid. BACKGROUND: AS-amyloid affects 1 in 7 elderly patients referred for transcatheter aortic valve replacement (TAVR). Bone scintigraphy with exclusion of a plasma cell dyscrasia can diagnose transthyretin-related cardiac amyloid noninvasively, for which novel treatments are emerging. Amyloid interstitial expansion increases the myocardial extracellular volume (ECV). METHODS: Patients with severe AS underwent bone scintigraphy (Perugini grade 0, negative; Perugini grades 1 to 3, increasingly positive) and routine TAVR evaluation CT imaging with ECVCT using 3- and 5-min post-contrast acquisitions. Twenty non-AS control patients also had ECVCT performed using the 5-min post-contrast acquisition. RESULTS: A total of 109 patients (43% male; mean age 86 ± 5 years) with severe AS and 20 control subjects were recruited. Sixteen (15%) had AS-amyloid on bone scintigraphy (grade 1, n = 5; grade 2, n = 11). ECVCT was 32 ± 3%, 34 ± 4%, and 43 ± 6% in Perugini grades 0, 1, and 2, respectively (p < 0.001 for trend) with control subjects lower than lone AS (28 ± 2%; p < 0.001). ECVCT accuracy for AS-amyloid detection versus lone AS was 0.87 (0.95 for 99mTc-3,3-diphosphono-1,2-propanodicarboxylic acid Perugini grade 2 only), outperforming conventional electrocardiogram and echocardiography parameters. One composite parameter, the voltage/mass ratio, had utility (similar AUC of 0.87 for any cardiac amyloid detection), although in one-third of patients, this could not be calculated due to bundle branch block or ventricular paced rhythm. CONCLUSIONS: ECVCT during routine CT TAVR evaluation can reliably detect AS-amyloid, and the measured ECVCT tracks the degree of infiltration. Another measure of interstitial expansion, the voltage/mass ratio, also performed well.


Assuntos
Amiloidose , Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/cirurgia , Feminino , Humanos , Masculino , Valor Preditivo dos Testes , Volume Sistólico , Tomografia Computadorizada por Raios X , Resultado do Tratamento , Função Ventricular Esquerda
13.
JACC Cardiovasc Imaging ; 13(6): 1353-1363, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-32498921

RESUMO

OBJECTIVES: To assess whether single-photon emission computed tomography (SPECT/CT) quantification of bone scintigraphy would improve diagnostic accuracy and offer a means of quantifying amyloid burden. BACKGROUND: Transthyretin-related cardiac amyloidosis is common and can be diagnosed noninvasively using bone scintigraphy; interpretation, however, relies on planar images. SPECT/CT imaging offers 3-dimensional visualization. METHODS: This was a single-center, retrospective analysis of 99mTc-3,3-diphosphono-1,2-propanodicarboxylic acid (DPD) scans reported using the Perugini grading system (0 = negative; 1 to 3 = increasingly positive). Conventional planar quantification techniques (heart/contralateral lung, and heart/whole-body retention ratios) were performed. Heart, adjacent vertebra, paraspinal muscle and liver peak standardized uptake values (SUVpeak) were recorded from SPECT/CT acquisitions. An SUV retention index was also calculated: (cardiac SUVpeak/vertebral SUVpeak) × paraspinal muscle SUVpeak. In a subgroup of patients, SPECT/CT quantification was compared with myocardial extracellular volume quantification by CT imaging (ECVCT). RESULTS: A total of 100 DPD scans were analyzed (patient age 84 ± 9 years; 52% male): 40 were Perugini grade 0, 12 were grade 1, 41 were grade 2, and 7 were grade 3. Cardiac SUVpeak increased from grade 0 to grade 2; however, it plateaued between grades 2 and 3 (p < 0.001). Paraspinal muscle SUVpeak increased with grade (p < 0.001), whereas vertebral SUVpeak decreased (p < 0.001). The composite parameter of SUV retention index overcame the plateauing of the cardiac SUVpeak and increased across all grades (p < 0.001). Cardiac SUVpeak correlated well (r2 = 0.73; p < 0.001) with ECVCT. Both the cardiac SUVpeak and SUV retention index had excellent diagnostic accuracy (area under the curve [AUC]: 0.999). The heart to contralateral lung ratio performed the best of the planar quantification techniques (AUC: 0.987). CONCLUSIONS: SPECT/CT quantification in DPD scintigraphy is possible and outperforms planar quantification techniques. Differentiation of Perugini grade 2 or 3 is confounded by soft tissue uptake, which can be overcome by a composite SUV retention index. This index can help in the diagnosis of cardiac amyloidosis and may offer a means of monitoring response to therapy.


Assuntos
Neuropatias Amiloides Familiares/diagnóstico por imagem , Cardiomiopatias/diagnóstico por imagem , Difosfonatos/administração & dosagem , Compostos de Organotecnécio/administração & dosagem , Compostos Radiofarmacêuticos/administração & dosagem , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único , Idoso , Idoso de 80 Anos ou mais , Osso e Ossos/diagnóstico por imagem , Feminino , Humanos , Masculino , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Estudos Retrospectivos , Índice de Gravidade de Doença , Imagem Corporal Total
14.
Eur Heart J ; 41(29): 2759-2767, 2020 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-32267922

RESUMO

AIMS: Cardiac amyloidosis is common in elderly patients with aortic stenosis (AS) referred for transcatheter aortic valve implantation (TAVI). We hypothesized that patients with dual aortic stenosis and cardiac amyloid pathology (AS-amyloid) would have different baseline characteristics, periprocedural and mortality outcomes. METHODS AND RESULTS: Patients aged ≥75 with severe AS referred for TAVI at two sites underwent blinded bone scintigraphy prior to intervention (Perugini Grade 0 negative, 1-3 increasingly positive). Baseline assessment included echocardiography, electrocardiogram (ECG), blood tests, 6-min walk test, and health questionnaire, with periprocedural complications and mortality follow-up. Two hundred patients were recruited (aged 85 ± 5 years, 50% male). AS-amyloid was found in 26 (13%): 8 Grade 1, 18 Grade 2. AS-amyloid patients were older (88 ± 5 vs. 85 ± 5 years, P = 0.001), with reduced quality of life (EQ-5D-5L 50 vs. 65, P = 0.04). Left ventricular wall thickness was higher (14 mm vs. 13 mm, P = 0.02), ECG voltages lower (Sokolow-Lyon 1.9 ± 0.7 vs. 2.5 ± 0.9 mV, P = 0.03) with lower voltage/mass ratio (0.017 vs. 0.025 mV/g/m2, P = 0.03). High-sensitivity troponin T and N-terminal pro-brain natriuretic peptide were higher (41 vs. 21 ng/L, P < 0.001; 3702 vs. 1254 ng/L, P = 0.001). Gender, comorbidities, 6-min walk distance, AS severity, prevalence of disproportionate hypertrophy, and post-TAVI complication rates (38% vs. 35%, P = 0.82) were the same. At a median follow-up of 19 (10-27) months, there was no mortality difference (P = 0.71). Transcatheter aortic valve implantation significantly improved outcome in the overall population (P < 0.001) and in those with AS-amyloid (P = 0.03). CONCLUSIONS: AS-amyloid is common and differs from lone AS. Transcatheter aortic valve implantation significantly improved outcome in AS-amyloid, while periprocedural complications and mortality were similar to lone AS, suggesting that TAVI should not be denied to patients with AS-amyloid.


Assuntos
Amiloidose , Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Feminino , Humanos , Masculino , Prevalência , Qualidade de Vida , Fatores de Risco , Tomografia Computadorizada por Raios X , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
15.
Med Eng Phys ; 76: 79-87, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31866119

RESUMO

CT-based computations of fractional flow reserve (FFR) have been widely utilized for evaluating functional severity of a coronary artery stenosis. Whilst this approach has been successful clinically, assumptions involved in the analysis still need to be investigated for further improvement in predictive accuracy. To better understand the sensitivity of computational FFRs on outflow boundary condition - typically reflecting patient's own physiology only through anatomical features - FFR computations for 10 patients with different degree of stenosis was conducted. The computations were based on 3D anatomical model reconstructed from CT images and patient-specific in/outflow boundary conditions (BC). Two outflow BCs were considered: (1) conventional morphology-based and (2) PET perfusion-based conditions. The results showed that the FFRs derived from the two boundary conditions agree in general. It was also found that the FFRs computed with the morphology-based BC tend to estimate higher functional severity, especially in patients with reduced vasodilatory response under hyperaemia - an essential physiological condition in FFR measurement. Further investigation was made by varying hyperaemic resistances (30%-90% of the baseline) in the morphology-based BC. The variation of FFR for the varied resistances was narrow for patients with mild stenosis and wider for those who have severe stenosis. This latter approach confirmed that variability of FFR due to outflow condition tends to come from overestimation of vasodilatory response, especially those who have abnormal myocardial perfusion. The results suggest that outflow conditions that are more representative of each patient could be an effective way to improve CT-based FFR computation.


Assuntos
Reserva Fracionada de Fluxo Miocárdico , Tomografia por Emissão de Pósitrons , Tomografia Computadorizada por Raios X , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/fisiopatologia , Feminino , Humanos , Imageamento Tridimensional , Masculino , Pessoa de Meia-Idade , Modelagem Computacional Específica para o Paciente
16.
Curr Treat Options Oncol ; 20(9): 73, 2019 08 08.
Artigo em Inglês | MEDLINE | ID: mdl-31396720

RESUMO

OPINION STATEMENT: Early detection and treatment of cardiotoxicity from cancer therapies is key to preventing a rise in adverse cardiovascular outcomes in cancer patients. Over-diagnosis of cardiotoxicity in this context is however equally hazardous, leading to patients receiving suboptimal cancer treatment, thereby impacting cancer outcomes. Accurate screening therefore depends on the widespread availability of sensitive and reproducible biomarkers of cardiotoxicity, which can clearly discriminate early disease. Blood biomarkers are limited in cardiovascular disease and clinicians generally still use generic screening with ejection fraction, based on historical local expertise and resources. Recently, however, there has been growing recognition that simple measurement of left ventricular ejection fraction using 2D echocardiography may not be optimal for screening: diagnostic accuracy, reproducibility and feasibility are limited. Modern cancer therapies affect many myocardial pathways: inflammatory, fibrotic, metabolic, vascular and myocyte function, meaning that multiple biomarkers may be needed to track myocardial cardiotoxicity. Advanced imaging modalities including cardiovascular magnetic resonance (CMR), computed tomography (CT) and positron emission tomography (PET) add improved sensitivity and insights into the underlying pathophysiology, as well as the ability to screen for other cardiotoxicities including coronary artery, valve and pericardial diseases resulting from cancer treatment. Delivering screening for cardiotoxicity using advanced imaging modalities will however require a significant change in current clinical pathways, with incorporation of machine learning algorithms into imaging analysis fundamental to improving efficiency and precision. In the future, we should aspire to personalized rather than generic screening, based on a patient's individual risk factors and the pathophysiological mechanisms of the cancer treatment they are receiving. We should aspire that progress in cardiooncology is able to track progress in oncology, and to ensure that the current 'one size fits all' approach to screening be obsolete in the very near future.


Assuntos
Cardiotoxicidade/diagnóstico por imagem , Cardiotoxicidade/etiologia , Diagnóstico por Imagem , Neoplasias/complicações , Protocolos de Quimioterapia Combinada Antineoplásica/efeitos adversos , Protocolos de Quimioterapia Combinada Antineoplásica/uso terapêutico , Biomarcadores , Cardiotoxicidade/fisiopatologia , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/etiologia , Diagnóstico por Imagem/efeitos adversos , Diagnóstico por Imagem/métodos , Humanos , Imagem Multimodal/métodos , Isquemia Miocárdica/diagnóstico , Isquemia Miocárdica/etiologia , Neoplasias/tratamento farmacológico , Disfunção Ventricular
17.
Pediatr Radiol ; 49(10): 1285-1298, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-31332480

RESUMO

BACKGROUND: Whole-body MRI is used for staging paediatric Hodgkin lymphoma, commonly using size thresholds, which fail to detect disease in normal-size lymph nodes. OBJECTIVE: To investigate quantitative whole-body MRI metrics for nodal characterisation. MATERIALS AND METHODS: Thirty-seven children with Hodgkin lymphoma underwent 1.5-tesla (T) whole-body MRI using short tau inversion recovery (STIR) half-Fourier-acquisition single-shot turbo-spin-echo and diffusion-weighted imaging (DWI). 18Flourine-2-fluoro-2-deoxyglucose (FDG) positron emission tomography (PET)/CT was acquired as the reference standard. Two independent readers assessed 11 nodal sites. The readers measured short-axis-diameter, apparent diffusion coefficient, (ADC) and normalised T2-signal intensity of the largest lymph node at each site. We used receiver operating characteristics (ROC)/area-under-the-curve (AUC) analysis for each MRI metric and derived sensitivity and specificity for nodes with short-axis diameter ≥10 mm. Sub-analysis of sensitivity and specificity was performed with application of ADC cut-off values (<0.77, <1.15 and <1.79×10-3 mm2 s-1) to 5- to 9-mm nodes. RESULTS: ROC/AUC values for reader 1/reader 2 were 0.80/0.80 and 0.81/0.81 for short-axis-diameter measured using DWI and STIR half-Fourier-acquisition single-shot turbo spin echo, respectively; 0.67/0.72 for normalised T2 signal intensity and 0.74/0.67 for ADC. Sensitivity and specificity for a short-axis diameter ≥10 mm were 84.2% and 66.7% for Reader 1 and 82.9% and 68.9% for Reader 2. Applying a short-axis-diameter ≥10-mm threshold followed by ADC cut-offs to normal-size 5- to 9-mm nodes resulted in sensitivity and specificity for Reader 1 of 88.8% and 60%, 92.1% and 56.7%, and 100% and 16.7%; and for Reader 2, 86.1% and 67.2%, 95.3% and 65.6%, and 100% and 19.7%; and ADC thresholds of <0.77, <1.15, and <1.79×10-3 mm2 s-1, respectively. CONCLUSION: Nodal size measurement provides the best single classifier for nodal disease status in paediatric Hodgkin lymphoma. Combined short-axis diameter and ADC thresholds marginally improve sensitivity and drop specificity compared with size classification alone.


Assuntos
Doença de Hodgkin/diagnóstico por imagem , Doença de Hodgkin/patologia , Linfonodos/patologia , Imageamento por Ressonância Magnética/métodos , Imagem Corporal Total/métodos , Adolescente , Benchmarking , Criança , Feminino , Humanos , Masculino , Estadiamento de Neoplasias , Sensibilidade e Especificidade
18.
J Nucl Med ; 60(8): 1087-1093, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-30683766

RESUMO

Guidelines recommend true whole-body 18F-FDG PET/CT scans from vertex to toes in pediatric lymphoma patients, although this suggestion has not been validated in large clinical trials. The objective of the study was to evaluate the incidence and clinical impact of lesions outside the "eyes to thighs" regular field of view (R-FOV) in 18F-FDG PET/CT staging (sPET) and interim (iPET) scans in pediatric lymphoma patients. Methods: True whole-body sPET and iPET scans were prospectively obtained in pediatric lymphoma patients (11 worldwide centers). Expert panel central review of sPET and iPET scans were evaluated for lymphoma lesions outside the R-FOV and clinical relevance of these findings. Results: A total of 610 scans were obtained in 305 patients. The sPET scans did not show lesions outside the R-FOV in 91.8% of the patients, whereas in 8.2% patients the sPET scans demonstrated lesions also outside the R-FOV (soft tissue, bone, bone marrow, and skin); however, the presence of these lesions did not change the clinical stage of any patient and did not affect treatment decision. Among the 305 iPET scans, there were no new positive 18F-FDG-avid lesions outside the R-FOV, when compared with their paired sPET scans. A single lesion outside the R-FOV on iPET occurred in 1 patient (0.3%), with the primary lesion diagnosed in the femur on sPET that persisted on iPET. Conclusion: The identification of additional lesions outside the R-FOV (eyes to thighs) using 18F-FDG PET/CT has no impact in the definition of the clinical stage of disease and minimal impact in the treatment definition of patients with pediatric lymphoma. As so, R-FOV for both sPET and iPET scans could be performed.


Assuntos
Fluordesoxiglucose F18/farmacologia , Linfoma/diagnóstico por imagem , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Adolescente , Criança , Pré-Escolar , Feminino , Doença de Hodgkin/diagnóstico por imagem , Humanos , Lactente , Linfoma não Hodgkin/diagnóstico por imagem , Masculino , Estudos Prospectivos , Reprodutibilidade dos Testes , Imagem Corporal Total/métodos
19.
J Interv Cardiol ; 31(5): 648-654, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-29900591

RESUMO

OBJECTIVES: To evaluate solid embolization during transcatheter aortic valve implantation (TAVI) and correlate this with aortic valve calcification. BACKGROUND: There is a known stroke risk with TAVI, thought partly to be due to dislodgement of native aortic valve particles during implantation. However, to date there is little evidence that aortic valve calcification actually impacts embolic risk. METHODS: Transcranial Doppler (TCD) was performed on consecutive suitable patients undergoing TAVI, using hardware and software enabling differentiation between solid and gaseous emboli. Data was analyzed by time points during the TAVI procedure. These results were correlated with aortic valve calcification. RESULTS: TCD was successfully performed on 63 patients. The median number of solid emboli was 76.0. The most common time point for solid embolization was during valve positioning. Forty-five of these patients had an appropriate CT scan which could be analyzed for an Agatston calcium score. The mean scores in the aortic valve and aortic root were 3382.4 and 754.9. There were significant correlations between the total number of solid emboli and valve calcium score (P = 0.033) and solid emboli during valve positioning and valve calcium score (P = 0.035). There was no relationship between gaseous emboli and valve calcium score. CONCLUSIONS: TAVI is associated with significant solid particle embolization, with the most common time point being during valve positioning. Solid embolization correlates with aortic valve calcium score, suggesting that valve calcification is a factor in embolic risk. This should be taken into consideration along with other clinical factors when assessing embolic risk.


Assuntos
Estenose da Valva Aórtica , Valva Aórtica/patologia , Calcinose , Embolia , Complicações Intraoperatórias , Substituição da Valva Aórtica Transcateter/efeitos adversos , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Calcinose/diagnóstico por imagem , Calcinose/cirurgia , Ecocardiografia Doppler/métodos , Embolia/diagnóstico , Embolia/etiologia , Embolia/prevenção & controle , Feminino , Próteses Valvulares Cardíacas/efeitos adversos , Humanos , Complicações Intraoperatórias/diagnóstico , Complicações Intraoperatórias/etiologia , Complicações Intraoperatórias/prevenção & controle , Masculino , Risco Ajustado , Tomografia Computadorizada por Raios X/métodos , Substituição da Valva Aórtica Transcateter/métodos
20.
Front Cardiovasc Med ; 5: 34, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29670888

RESUMO

During Atrial Fibrillation (AF) more than 90% of the left atrial thrombi responsible for thromboembolic events originate in the left atrial appendage (LAA), a complex small sac protruding from the left atrium (LA). Current available treatments to prevent thromboembolic events are oral anticoagulation, surgical LAA exclusion, or percutaneous LAA occlusion. However, the mechanism behind thrombus formation in the LAA is poorly understood. The aim of this work is to analyse the hemodynamic behaviour in four typical LAA morphologies - "Chicken wing", "Cactus", "Windsock" and "Cauliflower" - to identify potential relationships between the different shapes and the risk of thrombotic events. Computerised tomography (CT) images from four patients with no LA pathology were segmented to derive the 3D anatomical shape of LAA and LA. Computational Fluid Dynamic (CFD) analyses based on the patient-specific anatomies were carried out imposing both healthy and AF flow conditions. Velocity and shear strain rate (SSR) were analysed for all cases. Residence time in the different LAA regions was estimated with a virtual contrast agent washing out. CFD results indicate that both velocity and SSR decrease along the LAA, from the ostium to the tip, at each instant in the cardiac cycle, thus making the LAA tip more prone to fluid stagnation, and therefore to thrombus formation. Velocity and SSR also decrease from normal to AF conditions. After four cardiac cycles, the lowest washout of contrast agent was observed for the Cauliflower morphology (3.27% of residual contrast in AF), and the highest for the Windsock (0.56% of residual contrast in AF). This suggests that the former is expected to be associated with a higher risk of thrombosis, in agreement with clinical reports in the literature. The presented computational models highlight the major role played by the LAA morphology on the hemodynamics, both in normal and AF conditions, revealing the potential support that numerical analyses can provide in the stratification of patients under risk of thrombus formation, towards personalised patient care.